Loading the 3D engine

FemtoBragg femtosecond gratings

Gratings written through the coating.

A femtosecond laser writes each grating straight into the fibre core. The coating stays on, the fibre keeps its strength, and nothing has to be stripped or recoated.

1450–1650 nm
Centre wavelength
20–99 %
Reflectivity
300 °C
Long-term, polyimide

How it measures

One wavelength comes back.

Broadband light travels down the core. The grating reflects one narrow band and lets the rest pass. Strain or temperature shifts that band, and the shift is the measurement.

1549 1550 nm 1551 R
Illustrative reflection peak. 3 dB bandwidth below 0.4 nm, side-lobe suppression above 15 dB when apodised.

FemtoBragg Array

Many gratings, one unbroken fibre.

An array is written point after point along a single length of fibre, each grating at its own wavelength. There are no splice points, so the fibre keeps its original mechanical strength from end to end.

> 15 mm
Grating spacing
2–12 mm
Grating length
± 0.25 nm
Wavelength accuracy

Use cases

Where these gratings are already at work.

Each scene is a system our manufacturer has delivered, shown as a simplified animation, with the customers it was delivered to. Every one opens as a 3D model you can turn and walk through, and the use cases page adds six more, from mines and dams to electric vehicle batteries.

Simplified animation, not to scale. The values shown are illustrative.

Fibre laser cavity mirrors

A grating with reflectivity up to 99 % at a chosen wavelength closes the cavity of a fibre laser, written directly into the fibre with no free-space optics.

Telecom filters

A narrow reflection band, under 0.4 nm at 3 dB, selects or rejects a single channel between 1450 and 1650 nm.

The range

Three ways to order a FemtoBragg grating.

Every parameter below can be made to order. Tell us the wavelength, reflectivity and layout you need and we will quote it.

FemtoBragg SStandard FemtoBragg HTHigh temperature FemtoBragg ArrayGrating string
CoatingAcrylatePolyimideAcrylate or polyimide
Operating temperature−40 to 85 °C−200 to 350 °C, 300 °C long-termSet by the coating
FormSingle grating or arraySingle grating or arrayArray, spacing above 15 mm
Typical useStrain, temperature, pressure and displacement sensingHigh-temperature strain, downhole, aerospaceMulti-point sensing on one fibre
Centre wavelength
1450–1650 nm
Wavelength accuracy
± 0.25 nm
Grating length
2–12 mm
Reflectivity
20–99 %
3 dB bandwidth
< 0.4 nm
Side-lobe suppression
> 15 dB, apodised
Fibre
Standard single-mode
Pigtail length
To order

Made to order

Tell us what you need. The factory builds to it.

Our manufacturer writes the gratings, packages the sensors and builds the interrogators itself, and OptiSentry is its exclusive distributor in Australia. A requirement outside the table above is an engineering job for the factory, not a reason to say no. You deal with us locally, on the specification and on the way you want to buy.

The technical side

Wavelength plan
Each grating anywhere from 1450 to 1650 nm, held to ± 0.25 nm, in any order along the fibre.
Spectral shape
Reflectivity from 20 to 99 %, grating length from 2 to 12 mm, apodised when side lobes matter.
Array layout
Grating count, spacing and lead lengths to your drawing, on one fibre with no splices.
Level of assembly
Bare grating, packaged sensor, interrogator or a complete monitoring system.

The commercial side

Quantity
One prototype, a pilot batch or volume supply.
Branding
OEM and private-label supply for sensor and system makers.
Documentation
A measured spectrum with every grating, and test records in your procurement format.
Terms
Quoted in Australian dollars, with delivery and payment terms agreed to suit how you buy.

Built by our manufacturer for its own customers

0.05 µmA flange gap sensor fine enough to catch a loosening blade-root bolt, developed for wind turbine operators.
−50 to 600 °CFlexible multi-point temperature sensors, developed by our manufacturer over five years with Airbus.
5,120 pointsA temperature-field system for battery storage, certified for fire-protection use in China.
  1. Send the requirementA drawing, a spec sheet or a description of the problem.
  2. Feasibility and quoteWe take it to the factory’s engineers. If part of it cannot be done as written, we say so and propose what can.
  3. SamplesGratings with their measured spectra, for your own tests.
  4. SupplyRepeat orders against the agreed specification, handled from Australia.